Peijia Medical Fluxcap® Balloon Guide Catheter Obtained NMPA Approval
2022-06-09 14:25:59

On June 8, 2022, Peijia Medical received the approval from the National Medical Products Administration of  the PRC (the “NMPA”) for the registration application of Fluxcap® Balloon Guide Catheter, making it the Company’s fourteenth NMPA approved neurointerventional product. 

图片0.png

Fluxcap® Balloon Guide Catheter is developed by Achieva Medical, a wholly-owned subsidiary of the  Company. It is designed to address the clinical needs for balloon guide catheters (“BGCs”) and is compatible  with 6F intermediate catheters or aspiration catheters. The product’s 0.087-inch large lumen shows great  compatibility. The reinforced layer with transition zones leads to a balance of proximal support and distal  flexibility, offering a stable passage for intracranial devices. The 0.75mm non-radiopaque segment at the tip  can reduce the blind spots of the physicians, thus improving the safety of the procedure. The compliant  balloon at its tip can block proximal flow and effectively prevent the thrombus from dislodging into the distal  vessels. Fluxcap® Balloon Guide Catheter is available in four effective lengths, which can satisfy various  clinical needs and benefit more patients. 


In mechanical thrombectomy, the balloon guide catheter is used to arrest the antegrade flow, effectively  preventing thrombus from escaping. In addition to offering a stable passage for intracranial devices, the  balloon guide catheter can reduce the number of passes and therefore shorten the recanalization time. The  product is also associated with higher mTICI3 recanalization, which significantly improves the clinical  outcome of patients. In recent years, the safety and efficacy of BGCs in mechanical thrombectomy has been  confirmed, evidenced by the publication of a number of high-quality clinical studies. 

图片00.png

The approval of Fluxcap® Balloon Guide Catheter marks that Achieva is able to provide a complete solution for acute ischemic stroke. Its product line includes Fluxcap® Balloon Guide Catheter, Syphonet® Stent Retriever, Tethys AS® Aspiration Catheter, Tethys® Intermediate Catheter, Presgo® Micro Guidewire  and Presgo® Microcatheter. Achieva will continue to facilitate the construction of domestic stroke centers and  popularize the interventional treatment of acute ischemic stroke patients.

  • Prev: NMPA APPROVAL FOR REGISTRATION APPLICATION OF DCwire™ MICRO GUIDEWIRE
  • Next: Three Ischemic Products Approved by NMPA within Two Months